FNN-3200 Plane Electronic Compass
1 .Product Features
(1)Through two-axis magnetoresistive sensor measures plane Earth's magnetic field, and translates the measurements into heading information.
(2)High-speed and high-precision A / D conversion. The accuracy of magnetic field measurement is 100μGuass.
(3)Embedded microprocessors calculate the angle between sensor and Magnetic North.
(4)Operating temperature is -40℃to+85℃. Storage temperature is -55℃to+100℃.
2. Main Parameters (RT test):
Characteristic | Condition | Min | Typical | Max | unit |
Supply voltage | Direct-current | 4.5 | 5 | 5.5 | V |
Working current | Supply voltage = 5V | 30 | 35 | 40 | mA |
Settling Time | 5 | sec | |||
Field range | Ambient magnetic field environment | -2 | 2 | Gauss | |
Accuracy | After user calibration | ±1 | º | ||
Resolution | ±0.2 | º | |||
Linear | ±0.7 | ±1 | % | ||
Repeatability | ±0.4 | º | |||
stability | Interval 24 hours | ±0.6 | º | ||
Thermal zero drift | Temperature range: -40 ℃ -85 ℃ | ±0.04 | ±0.06 | º/℃ | |
Maximum magnetic interference+1
| 20 | Gauss | |||
Data update rate | Output continuous output | 3 | Hz | ||
Baud Rate | RS232、RS485、TTL | 9600 | Baud | ||
Communication parameters | RS232、RS485、TTL | 9600,n,8,1 | |||
storage temperature | Ambient temperature | -50 | 90 | ℃ | |
Operating temperature | Ambient temperature | -40 | 80 | ℃ | |
weight | Uncased(PCB50)*2 | 10 | 12 | 14 | g |
Uncased(PCB35)*2 | 4 | 6 | 8 | g | |
size | Uncased(PCB50)*2 | Diameter: 50 Height: 18 | mm | ||
Uncased(PCB35)*2 | Diameter: 50 Height: 16 | mm |